Before and After — LED relight/retrofit

The below un-altered photographs of “Before” and “After” installations demonstrate LEDs superior characteristics of lighting. LED performance provides better visual acuity and better uniformity which is all achieved while using less energy! Spaulding's Cimarron LED fixtures integrate the latest LED advancements and deliver optical performance that can perform as well as, and in most cases, better than traditional HID fixtures. Additionally, HID/LED comparison charts and sample project cost savings are provided to estimate savings or traditional lighting sources.

 

Kevin Whitaker Chevrolet

Working with Kevin Whitaker Chevrolet, the lighting designers at Net Zero USA chose three different Hubbell Lighting outdoor LED products to make the cars and trucks' paint truly pop. Over one hundred 1000 watt metal halide fixtures at the tops of existing poles were replaced with 332 watt Spaulding Lighting Cimarron LED luminaires. Forty-four 250 watt small metal halide floodlights located halfway down some of the front line inventory poles were swapped out with forty-four 70 watt Hubbell Outdoor Lighting Miniliter LED floodlights. And a dozen 1000 watt metal halide floodlights on the exterior of the building were updated with fourteen 107 watt Hubbell Outdoor Lighting Magnuliter LED floodlights.

Inside the showroom and office space, the dealership chose products from Hubbell Lighting's Columbia Lighting and Prescolite brands to provide an inviting atmosphere for customers and showcase vehicles in the showroom.

Link to complete case study. Kevin Whitaker Chevrolet Case StudyLED Area/Site Products

Before

Before with HID

After

After with LED

TD Convention Center

The parking lot lighting at the TD Convention Center is a prime example for the future of LED lighting.The parking area was lit with 400w HPS fixtures mounted in double configuration at 28 feet. These fixtures were replaced with Cimarron 90LED 210w fixtures on the existing poles. The results included energy-savings of 55% over HPS, improved overall uniformity and a safely illuminated parking area. Reference the HID/LED Comparison chart below for savings of LED systems compared to PSMH and HPS lighting systems.

Link to complete case study. TD Convention Center Case StudyLED Area/Site Products

Before

400w HPS units, double configuration, mounted at 28 ft.

After

Cimarron 90LED units, double configuration, mounted at 28 ft.

ABQ International Sunport

The parking area lighting at the Albuquerque International Sunport is another prime example of the benefits of relighting with LED lighting. The parking area was lit with 400w metal halide fixtures mounted in single and double configurations at 25 and 30 feet. These fixtures were replaced with Cimarron 90LED 210w fixtures on the existing poles. The results included energy-savings of 54% over MH, improved overall uniformity and a safely illuminated parking area.

Link to complete case study. ABQ International Sunport Case StudyLED Area/Site Products

Before

400w MH luminaires, mounted at 25 and 30 ft.

After

Cimarron 90LED luminaires, mounted at 25 and 30 ft.

HID/LED Comparison

HID System HID Wattage HID Life Hours1 LED wattage2 LED life Hours3 Savings
150w PSMH 185 15,000 70 60,000 63%
250w PSMH 283 15,000 140 60,000 51%
320w PSMH 361 20,000 210 60,000 42%
400w PSMH 459 20,000 210 60,000 54%
100w HPS 130 24,000 70 60,000 47%
250w HPS 295 24,000 140 60,000 53%
400w HPS 464 24,000 210 60,000 55%
NOTE:
  1. Hours of life based on 50% mortality.
  2. Actual wattage should be confirmed with site specific lighting calculations.
  3. LED hours of life based on 70% of initial illumination.

HID/LED Energy & Maintenance Comparison

Annual Energy Costs
Luminaire 400 MH HID Shoebox Cimarron LED - 90
Cost Per KWH $0.10
Operating Hrs / Day 12
Fixture Qty 117 117
Input Watts per fixture 460 210
Annual Hours On per fixture 4380 4380
Annual KW 235,732 107,617
Annual Energy Costs $23,573.16 $10,761.66
Annual operation savings with new LED system $12,811.50
Annual Maintenance Costs
Expected Relamp & Maintenance Costs Per Luminaire (parts, labor, disposal, and lift rental per instance) $150 $0
Lamp Life (rated hrs) 20,000 60,000
Expected Lamp Life In Years Given Annual Operating Hours 4.57 13.70
Percentage of Lamp Life Consumed Each Year 22% 7%
Annualized Maintenance Costs (per luminaire) $32.85 $0.00
Annualized Maintenance Costs (entire site) $3,843.45 $0.00
End Of Lamp Life Maintenance Cost (entire site) $17,550.00 $0.00
Annual maintenance savings with new LED system $3,843.45
Annual Energy & Maintenance Summary
Annualized Energy Costs (entire site) $23,573.16 $10,761.66
Annualized Maintenance Costs (entire site) $3,843.45 $0
Total Annualized Cost $27,416.61 $10,761.66
Estimated annual savings $16,654.95