Brand: Electro Composites
Catalog ID: 200-012-B-168-01
Electro Composites SDC™ composite bushings are designed to provide the toughest, cleanest and safest bushing solution for all HV applications. We make standard OEM and aftermarket form-fit-function replacement bushings for substation transformers, GSU transformers, oil circuit breakers, switchgear, wall/floor (air-air and oil-oil), HVDC and other applications. Available from 1kV up to 170kV with current ratings up to 21,500A. SDC™ (Solid Dielectric Capacitor) bushings have a one-piece cycloaliphatic epoxycore and integral sheds. All SDC bushings are solid dielectric insulation – oil–free construction, capacitance graded condenser core with internal CT pocket/ground shield and a flange test tap, available in bottom connected or draw-lead configurations. Made in accordance with the most current bushing standards: IEEE C57.19.01, CSA C88.1, IEC 60137.
For Bushing Test Terminals, please see here
Application
OCB
Bottom Terminal Type
1 1/2-14
Catalog Number
200-012-B-168-01
Color
Gray
Immersion Type - Above Flange
Air
Immersion Type - Below Flange
Oil
Material - Flange
Aluminum
Material - Insulation
APG-02 - Cycloaliphatic Epoxy
Mounting Position
Vertical to Horizontal
Number of Flange Mounting Holes
4
Plating - Bottom Terminal
None
Test Tap
No
Top Terminal Plating
None
Top Terminal Type
1 1/2-14
Type
SDC - Solid Dielectric Capacitor
Above Flange Length
29.5 in
Below Flange Length
30 in
Diameter - Above Flange Maximum
8.64 in
Diameter - Below Flange Maximum D <gt/> 1"
3.29 in
Diameter - Below Flange Maximum P
3.29 in
Diameter - Conductor Outside Under Insulation
1.5 in
Diameter - Live Part Bottom
1.50 in
Diameter - Live Part Top
3.00 in
Diameter - Rod / Tube
1.5 in
Dimensions
59.50 in x 9.8 in x 13.86 in
Effective Length - Bottom Terminal
2.50 in
Effective Length - Top Terminal
3.00 in
Flange Mounting Hole Bolt Circle
7.5 in
Flange Mounting Hole Diameter
0.88 in
Flange Outside Diameter
6.93 in
Height
13.86 in
Length
59.5 in
Length - Ground Shield
12.50 in
Length - Insulated Section
51.5 in
Length - Insulation Above Flange
20.50 in
Length - Insulation Below Flange
13.90 in
Length - Live Part Bottom
3.60 in
Length - Live Part Top
4.50 in
Length - Minimum Oil Immersion Level
12.50 in
Sealing Surface Inside Diameter
4.38 in
Sealing Surface Outside Diameter
5.88 in
Thickness
0.895 in
Top Terminal Min. Thread Length
3 in
Weight
81 lb
Width
9.8 in
BIL
200 kV
Current Rating
1200 A
kV Class
34.5 kV
Minimum Creepage
45.4 in
Minimum Strike
22.8 in
Withstand Voltage - 60 Hz Dry
80 kV
Industry Standard(s)
IEEE C57.19.01