DDX9121b


Installation and/or Update Instructions

Following instructions are valid for a new installation and also for update to the latest Remote Software version

Make sure your device is a DDX9121b.
For previous models (DDX9121 and DDX9121a)
 please refers to this web-page -> http://update.haefely.com/ddx91x1/
  • Download the last "complete version" zipped file to your computer - name DDX9121b_complete_X_X_X_X.zip
  • Extract all files into a new directory in the computer you want to install. 
    Note -> It is not possible to install the files from a compressed file.
  • Double click in the "setup.exe" file 
  • Wait until the installation is complete

Note: File "DDX9121b_executable_X_X_X_X.zip" is determined for manual update, which is not recommended. 

Computer (remote) software 

Version 
Changes 
Download
Complete version 7.3.0.0
  • New

- Freely selectable Table Report Update Interval (Setup -> Report Setup)
- Possibility to Save and Load customized Remote Software settings (PD SCOPE Settings orange button -> Advanced -> Settings)
- Site Location (SL) tab available in Office mode

  •  Fixed

- Losing the Report Setup settings after Remote Software restart (Setup -> Report Setup) – fixed
- Several small bugs fixes

DDX9121b_complete_7_3_0_0.zip
Complete version 7.1.0.0
  • New

- NQP diagram - manual Q- axis range settings (supports full resolution) - helps in case of multiple diagrams comparison or to avoid unwanted Q- axis scale change caused by random external noise with high amplitude (crane move)
- DC mode - "Q vs Time" diagram - manual Q- axis range settings (supports full resolution) - advantages as mentioned in case of NQP
- DC mode - "Q vs Time" diagram - possibility to enable/disable Post- processing

- Added hint during "Connecting to detectors"

  •  Improved

- NQP snapshot - statistical data and voltage level have been added
- Added possibility to freely edit snapshots' comments during and after measurement or in Office mode
- Added possibility to create new snapshots when measurement is finished or in Office mode (e.g. when Post- processing settings/limits in DC mode in "Q vs Time" diagram are changed)

  • Fixed
- Small settings and typo bugs in SL mode fixed
- Several small bugs fixes
DDX9121b_complete_7_1_0_0.zip
Complete version 7.0.0.0
  • New

- SL function - allows user to perform PD Cable Site/Fault Location
- New filter settings according to I
EC 60270:2015 implemented
- Digital PD Filter Output control settings

  •  Improved

- DC measurement data handling - SAVE and LOAD function
- Reporting tool - possibility to select arbitrary diagrams in Report

  • Fixed

- Incorrect Filter Settings and Detector Information in "Export to CSV" if done from Office Mode
- Several small bugs fixes
DDX9121b_complete_7_0_0_0.zip
Complete version 6.8.0.0
Executable version 6.8.0.0
  • New

- Calibration - "Copy to All" function - copy calibration factor to all inputs and also to all connected detectors and active inputs

  •  Improved

- Calibration process more stable
- "Default settings" button improved
- Post-processing feature in DC mode
- Q(V) pop-up warning message - possibility to deactivate
- Gating and filter settings notification

  • Fixed

- Data Logging "Stop button" bug
- Random lose of auto-scaling of PD-Scope diagram
- Feature - "Change IP"
- Display issue of PD diagrams settings - coloured background   
- Several small bugs fixes
DDX9121b_complete_6_8_0_0.zip

DDX9121b_executable_6_8_0_0.zip
Complete version 6.7.0.0
Executable version 6.7.0.0
  • New

- Manual voltage source synchronization feature
- Possibility to save PD calibration
- PD Calibration factors are displayed for all inputs
- Displaying of actual value of Average Discharge Current and Pulse Repetition Rate in given diagrams
- Cursor feature is available in all diagrams
- Snapshot auto-save mode
- Real voltage waveform reading diagram (including crest factor)

  •  Improved


- Post-processing feature in DC mode
- Pulse recognition technique
- Performance of the complete system
- Improved reporting (Qiec or Qpeak value is displayed, RIV value displayed only when RIV feature is available, frequency value is displayed, etc.)

  • Fixed

- PD scope y-axis auto-range is kept after calibration
- Automatic recognition of Loaded Test file - AC or DC
- Incorrect warning message in case of PD or V calibration
- Several small bugs fixes

DDX9121b_complete_6_7_0_0.zip

DDX9121b_executable_6_7_0_0.zip
Complete version 6.5.1.0
Executable version 6.5.1.0
  • New

- Office version for off-line analysis
- Changing detector IP settings possible
  • Improved
- Communications with Haefely OT-257
- PD scope Refreshing speed in multidetectors systems (Needs firmware version 1.2.1.0 or above)
  • Fixed
- NQP zoom window fixes.
- Several small bugs fixes.
- Error while measuring band selection (6.5.0.0)

NOTE

The version 6.5.0.0 has been removed due to a bug in the frequency band selection, if your detector is equipped with this version must be updated to the latest available version.
DDX9121b_complete_6_5_1_0.zip

DDX9121b_executable_6_5_1_0.zip

Complete version 6.1.0.0
Executable version 6.0.0.0
  • New

- New data logging parameters Discharge Current I(t) and repetition rate N(t) in advance mode.
- Scope window can be maximized to full screen.
  • Improved
- Computer default HTML viewer for reports.
- Detector detection at software starting.
- NQP Bipolar added.
- NQP performance improvements.
  • Fixed
- NQP zoom window fixes.
- Several small bugs fixes.
DDX9121b_complete_6_1_0_0.zip

DDX9121b_executable_6_1_0_0.zip
Executable version 6.0.0.0Release versionDDX9121b_complete_6_0_0_0.zip

DDX9121b_executable_6_0_0_0.zip

Device Firmware

For device firmware update please follow the instructions in the instruction manual .

Version 
Change History
Files for Download
Executable version 1.3.6.0- Site Location pulse recognition improvementDDX9121b_firmware _1_3_6_0.zip
Executable version 1.3.3.0- Pulse recognition improved.DDX9121b_firmware _1_3_3_0.zip
Executable version 1.2.1.0- Change of the detector IP address posible
- Speed performance increased on multidetector systems (needs remote software 6.3.0 or above)
- Clean all previous settings in the detector
DDX9121b_firmware _1_2_1_0.zip
Executable version 1.0.4.0- Several small bugs fixedDDX9121b_firmware _1_0_4_0.zip
Executable version 1.0.0.0- Release versionDDX9121b_firmware _1_0_0_0.zip  

KAL9530 Calibrator libraries

The Agilent/Keysight libraries are needed to connect the DDX9121b remote software to the KAL9530 and perform automatic RIV calibrations
For installation please refers to the DDX9121b corresponding chapter.

Version 
Change History
Links
See Agilent/Keysight link (latest version)See Agilent/Keysight link (supporting latest version of Windows)Agilent/Keysight IO libraries - Latest Version
Version 16.3Agilent/Keysight IO libraries - Version 16.3 supporting Windows XPAgilent/Keysight IO libraries - Version 16.3
Installation Guide - version 1.0The Keysight/Agilent Installation GuideThe Keysight/Agilent Installation Guide

 

Documents

DocumentVersionFile for download
Instruction Manual 7.3.0.0Remote Control SW V7.3.0.0 Updates
Formating bugs fixes.
DDX9121b_Instruction_manual_7_3_0_0
Instruction Manual 7.0.0.0SL function
Analog outputs description
DDX 9121b Remote Control SW V7.0.0.0
DDX9121b_Instruction_manual_7_0_0_0
Instruction Manual 6.1.0.0Multidetector information added
Office mode added
Advance mode added
Several bug fixed
DDX9121b_Instruction_manual_6_1_0_0
Instruction Manual 6.0.0.0Release version of the manualDDX9121b_Instruction_manual_6_0_0_0